MICROSTREAM Flowmeter 
Instantaneous Flow-Rate·Integrating Flow Volume Flowmeter
Model OF-WN (Local display type)
Model OF-WP (With pulse output)
Features
- Built-in lithium batteries (No external power supply is required)
- Indications of both instantaneous flow-rate and integrating flow volume by only 1 flowmeter
- Revolving display unit (It can be fixed to a easy-to-read position)
- Simplified structure with the oval gears type measuring principle
- Measurement of various liquids
- Reset function for indications of Integrating Flow Volume (Total) and Integrating Flow Volume (Trip)
- Value holding function for Instantaneous Flow-Rate indication
- Pulse output function (Option)
Specifications
| Instantaneous flow-rate・ Integrating flow volume flowmeter OF-WN Type |
OF05ZAWN | OF10ZAWN | ||
|---|---|---|---|---|
| Instantaneous flow-rate・ Integrating flow volume flowmeter (with pulse output) OF-WP Type |
OF05ZAWP | OF10ZAWP | ||
| Flow-rate range (m3/h) |
Fluid viscosity 0.3 ~ 0.8mPa·S |
0.085 ~ 0.85L/min | 0.7 ~ 5L/min | |
| 0.8 ~ 2.0mPa·S | 0.05 ~ 0.85L/min | 0.35 ~ 5L/min | ||
| 2.0 ~ 5.0mPa·S | 0.017 ~ 0.85L/min | 0.17 ~ 5L/min | ||
| 5.0 ~ 200mPa·S | 0.0085 ~ 0.85L/min | 0.085 ~ 5L/min | ||
| Accuracy (*1) |
Flow-rate indication | ±2%RS±0.007L/min | ±2% RS±0.04L/min | |
| Volume indication | ±2%RS | |||
| Measurable fluids |
Various liquids | Please select with reference to the following
major materials of the liquid-touching materials |
||
| Major fluids | Water, hot water, kerosene, heavy oil | |||
| Max. working pressure | 0.5MPa (at the time of fluid temperature of 20°C) | |||
| Pressure drop | Not more than 4kPa | Not more than 10kPa | ||
| Fluid temperature range | 0 ~ +60°C | |||
| Output signal (for OF-WP) |
|
|||
| Pulse unit (for OF-WP) | 10mL/p | |||
| Ambient temperature range | 0 ~ +60°C 35 ~ 85%RH (Dew condensation must be avoided) |
|||
| LCD | Flow-rate | Smallest Scale | 0.007L/min | 0.04L/min |
| Display digits | 0.000L/min | 00.00L/min | ||
| Volume | Smallest Scale | 0.001L | 0.01L | |
| Display digits | 00000.000L | 000000.00L | ||
| Power supply | Built-in lithium battery (Battery life 4 years. Not replaceable.) | |||
| Structure | IP64 equivalent, Indoor installation | |||
| Connection | R1/4 | R1/2 | ||
| Meter Weight | Approx. 240g | Approx. 260g | ||
| Major materials of the liquid touching parts |
Casing | PPS | ||
| Rotor | PPS | |||
| O-ring | NBR | |||
| Pivot | SUS304 | |||
| Instantaneous flow-rate・ Integrating flow volume flowmeter OF-WN Type |
OF05ZZWN | OF10ZZWN | ||
|---|---|---|---|---|
| Instantaneous flow-rate・ Integrating flow volume flowmeter (with pulse output) OF-WP Type |
OF05ZZWP | OF10ZZWP | ||
| Flow-rate range (m3/h) |
Fluid viscosity 0.3 ~ 0.8mPa·S |
0.085 ~ 0.85L/min | 0.7 ~ 5L/min | |
| 0.8 ~ 2.0mPa·S | 0.05 ~ 0.85L/min | 0.35 ~ 5L/min | ||
| 2.0 ~ 5.0mPa·S | 0.017 ~ 0.85L/min | 0.17 ~ 5L/min | ||
| 5.0 ~ 200mPa·S | 0.0085 ~ 0.85L/min | 0.085 ~ 5L/min | ||
| Accuracy (*1) |
Flow-rate indication | ±2%RS±0.007L/min | ±2% RS±0.04L/min | |
| Volume indication | ±2%RS | |||
| Measurable fluids |
Various liquids | Please select with reference to the following
major materials of the liquid-touching materials |
||
| Major fluids | Water, hot water, kerosene, heavy oil | |||
| Max. working pressure | 0.5MPa (at the time of fluid temperature of 20°C) | |||
| Pressure drop | Not more than 4kPa | Not more than 10kPa | ||
| Fluid temperature range | 0 ~ +60°C | |||
| Output signal (for OF-WP) |
|
|||
| Pulse unit (for OF-WP) | 10mL/p | |||
| Ambient temperature range | 0 ~ +60°C 35 ~ 85%RH (Dew condensation must be avoided) |
|||
| LCD | Flow-rate | Smallest Scale | 0.007L/min | 0.04L/min |
| Display digits | 0.000L/min | 00.00L/min | ||
| Volume | Smallest Scale | 0.001L | 0.01L | |
| Display digits | 00000.000L | 000000.00L | ||
| Power supply | Built-in lithium battery (Battery life 4 years. Not replaceable.) | |||
| Structure | IP64 equivalent, Indoor installation | |||
| Connection | R1/4 | R1/2 | ||
| Meter Weight | Approx. 240g | Approx. 260g | ||
| Major materials of the liquid touching parts |
Casing | PPS | ||
| Rotor | PPS | |||
| O-ring | FKM | |||
| Pivot | SiC | |||
- In case there is possibility that any particle is flown in the liquid to be measured, please install a filter of not less than 80 meshes at the inlet side of the flowmeter.
- Gasoline, Sodium hydroxide (Caustic soda), Hydrogen peroxide solution (Oxydol), and Hydrochloric acid are not applicable.
- *1: With the standard installation position.
External dimensions
| Model | OF05 | OF10 |
|---|---|---|
| A(mm) | 80 | 90 |
| B(mm) | 8 | 8.5 |
| C(mm) | 25 | 24 |

Standard installation position

Materials - Abbreviations
| PPS | Polyphenylene Sulfide Resin |
|---|---|
| NBR | Acrylonitrile-Butadiene Rubber |
| SUS304 | Stainless Steel 304 |
| FKM | Fluoro Rubber |
| SiC | Silicon Carbide Ceramic |